Yamada NDP-15 Series Pumps
15 GPM Maximum Capacity - 1/2" Port Size
- Polypropylene (PPG)* 1/2" Female NPT
- Kynar (PVDF)** 1/2" Female NPT
- Aluminum (ADC-12)*** 1/2" Female NPT
- Stainless Steel (316)*** 1/2" Female NPT
- 1/4" Female NPT (includes ball valve) Air exhaust
- 3/8" Female NPT (internal silencer)
- Neoprene: 180°F (82°C)
- Buna N: 180°F (82°C)
- Hytrel: 248°F (120°C)
- Santoprene: 225°F (107°C)
- Viton: 248°F (120°C)
- Teflon: (PTFE) 212°F (100°C)
- 20 to 100 PSI (1.4 to 7 kfg/cm)
- 0.0375 gallons (138 cc) Ball-type check valve
- 0.031 gallons (119 cc)
- All diaphragms: 400
- 1/32" (1 mm)
- Flat-type check valve: 8-feet
- Ball-type check valve: 5-feet
- Ryton air motor standard
Port Dimensions
Intake & discharge connection*Polypropylene pumps may be fitted with ball or flat check valves. Ball-type check valves are recommended for flooded suction applications. Flat-type check valves are recommended for suction lift applications.
**Kynar pumps are fitted with flat check valves only.
***Aluminum and Stainless Steel pumps are fitted with ball check valves only.
Air inletMaximum Liquid Temperature****
Diaphragm Material / Temperature****Polypropylene pumps have a maximum liquid temperature of 180°F (82°C) regardless of diaphragm material. Kynar pumps have a maximum temperature of 248°F (120°C) when fitted with Hytrel or Viton diaphragms.
Air Supply Pressure (All Models)
Discharge Volume Per Cycle
Flat-type check valveMaximum Cycles Per Minute
Maximum Size Solid
Maximum Dry Suction Lift
Pump Air Motor
Notes: Hytrel-fitted pumps include Buna N check balls & wetted o-rings. Santoprene-fitted pumps include EPDM check balls & wetted o-rings.
Click Here for the NDP5 & NDP15 Maintenance Manual